VFD Dust Explosion Proof Motor

In 2023, the VFD Dust Explosion Proof Motor TEDV3 developed and produced by Wuxi TECO Electric Co., Ltd. has already begun to accept orders. Welcome to order.

  • Brand: TECO
  • Type: TEDV3(EVEVXQ/EVVVXQ)

VFD Dust Explosion Proof Motor RATING:

  • MODEL :TEDV3 

  • TYPE :EVEVXQ/EVVVXQ

  • Kind of Motors:Squirrel - Cage Induction Motors ( SCIM ) . 

  • Design Standards:IEC , GB 

  • Voltages:

    Fr#80-Fr#100: 220V,230V,380V,400V,415V,440V,460V,480V,200/346V,220/380V,230/400V,             240/415V,254/440V,265/460V,277/480V,220-240/380-415V,380-415V ; 

    Fr#112-Fr#132: 220V,230V,380V,400V,415V,440V,460V,480V,525V,660V,690V,200/346V, 220/380V,230/400V,240/415V,254/440V,265/460V,277/480V,380/660V, 400/690V, 220-240/380-415V,380-415V; 

    Fr#160~Fr#355: 220V,230V,380V,400V,415V,440V,460V,480V,525V,660V,690V,1140V, 200/346V,220/380V,230/400V,240/415V,254/440V,265/460V,277/480V, 380/660V,400/690V, 660/1140V,220-240/380-415V,380-415V.

  • Frequency:50Hz . 

  • Torque Control:

    Contant torque:3-50Hz

    Contant Power:50-100Hz

    However,2P-45kW Above:Contant Power 50-60Hz

    4P-200kW Above:Contant Power 50-60Hz

  • Output Range:0.18 kW ~ 400 kW .

  • R.P.M. (Syn.) 3000 ~ 750 R.P.M. ( 2 ~ 8 Poles ) .

  • Time Duty:Continuous. S1 , S.F.:1.0 .

  • Frame Nos.:80M ~ 355 .

  • Protection Enclosure:Totally Enclosed ( IP 65 ) .

  • Cooling Method:Forced Ventilation Surface Cooled (IC416) .

  • Mounting:

    EVEVXQ : Horizontal Foot Mounted B3 ( IM 1001 ) . 

    EVVVXQ : Horizontal Flange Mounted B5 ( IM 3001 ) . 

    EVEVXQ : Horizontal Foot And Flange Mounted B35 ( IM 2001 ) . 

    EVVVXQ : Vertical Flange Mounted, Shaft Down V1 ( IM 3011 ) . 


VFD Dust Explosion Proof Motor Application:

  • Environment Conditions :

    Place : Zone 21 Hazadous . 

    Ambient Temperature:-20℃~40℃ . 

    Relative Humidity:Less Than 90%RH ( Non-Condensation ) . 

    Altitude:Less Than 1,000 Meters . 

  • Certification Marking /Hazardous Location:Extb IIIC T135℃ Db IP65/Suitable for Zone 21,Dust.

  • Power Source Conditions Voltage:±10%, Frequency:±5%, and 10% Max. of Combined Voltage and Frequency. But Frequency Variation Does Not Exceed ±5% .

  • Method of Starting:Full Voltage Direct On Line or Y - △ Starting .

电话咨询